Magnetic particles inspection

Magnetic particles inspection
CONTROMAG C20
Available for wet continuous fluorescent method and using HWDC.
Magnetic Ink : -MAGNAGLO 14A
Carrier liquid: -MAGNAFLUX Carrier II
Maximum distance between poles 90 cm
Maximum peak amperage for circular magnetization 4000 Amps.
Maximum value for longitudinal magnetization 24 kA-turns.

CONTROMAG C30
Available for wet continuous fluorescent method and using HWDC.
Magnetic Ink: -MAGNAGLO 14A
Carrier liquid: -MAGNAFLUX Carrier II
Maximum distance between poles 150 cm
Maximum peak amperage for circular magnetization 8000 Amps.
Maximum value for longitudinal magnetization 30 kA-turns.

MAGISCOPE CC 10000
Available for wet continuous fluorescent method and using HWDC.
Magnetic Ink : -MAGNAGLO 14A
Carrier liquid: -MAGNAFLUX Carrier II
Maximum distance between poles 160 cm
Maximum peak amperage for circular magnetization 12000 Amps.
Maximum value for longitudinal magnetization 30 kA-turns.