Inspection capabilities

Inspection capabilities

Conventional Areas

  • Height Gauges
    Type : TV 600/TV1200
    Range : 6001200 mm
    Accuracy / Resolution : 0,001 mm
    Manufacturer : Trimos
  • Blades Contour Projector
    Magnification 10X
    Screen dimensions 400×600 mm
    Accuracy : 0,1mm
    Type VERNON / ENGLAND
  • Universal Microscope
    Optical Measuring Machine 2D
    Range : 400×100×145 mm
    Accuracy / Resolution : 0,001 mm
    Type : MU314 / SWISS
  • Optical Measuring Machine 2D
    Range : 200×100 mm
    Accuracy / Resolution : 0,001 mm
    Type : 19 JA Links / China
  • Surface Texture
    Magnification range:
    x500÷x100.000(vertical)
    x4÷x100(horizontal)
    Meter cut off value: 0,25;0,8;2,5(mm)
    Total accuracy: 3%
    Type:TALYSURF
  • Projectors
    Magnification x10;x25;x50
    Screen dimensions 400×600 mm
    Screen dia.:1000 mm
    Worktable measuring capacity;
    X=350 mm
    Z=250 mm
    < =± 15o
    Type CYCLOP1 / ITALY
  • Position & Form Errors
    Magnification: 100 to 5000
    Dia of rotating palte: 200 mm
    Sensitivity : 0,1µm
    Accuracy :± 3% on recording
    Type:FEDERAL /USA
  • Magnification 100 to 5000
    Dia of rotating palte: 220 mm
    Sensitivity : 0,1µm
    Accuracy :± 3,3% on recording
    Type:TALYROND 100 / ENGLAND
  • Profile Errors
  • Serated Wheel
    Accuracy 0,001 mm
    Max. dia of Wheel:1000mm
    Type: VERNON / ENGLAND
  • Profile Graph
    Magnification range:
    x10÷x100 (vertical)
    x10÷x100 (horizontal)
    Total accuracy: 1%
    Range:100mm
    Country:JAPAN

3D Computer Measuring Machines Areas

  • ZEISS-PRISMO 10
    Accuracy 0,0029+L/250 mm
    Range 1200×1800×1000 mm
    Type ZEISS PRISMO10 / GERMANY
  • ZEISS-PRISMO 7
    Accuracy 0,0029+L/250 mm
    Range 900×1500×650 mm
    Type ZEISS PRISMO7 / GERMANY
  • Software
    Universal Measure System-Umex
    Free Form System-Holos
    Spiral Bevel Gears System
  • Gears Areas
  • Spacing Errors
    Magnification x250,x500,x1000
    Max. dia of wheel:1000mm
    Type HOFLER H1100/SWISS
  • Form Errors
    Base circle:20-600mm
    Module:0.5-20
    Helix:0-60°
    Magnification:500, 1000, 2000 X
    Type MAAG SP-60 / SWISS
  • Lead error-1 sec;
    Involute form errors -0.001mm;
    Module 0.5-20;
    Max. dia.:600mm;
    Type:KLINGENBERG PFS60/GERMANY
  • Universal Testers
    Patern and backlash inspection
    Max.dia 400 mm
    Max.distance between axes 254 mm
    Type GEASON 523 / ENGLAND
  • Patern and backlash inspection
    Max.dia 200 mm
    Max.distance between axes 125 mm
    Type GEASON 6 / ENGLAND
  • Composite Errors
    Composite errors
    Max.dia.:152mm
    Accuracy:0.002mm
    Type GOULDER MIKRON 6 / SWISS